Vulnerability Name: | CVE-2011-4537 (CCN-71931) | ||||||||
Assigned: | 2011-12-21 | ||||||||
Published: | 2011-12-21 | ||||||||
Updated: | 2017-08-29 | ||||||||
Summary: | Multiple buffer overflows in 7-Technologies (7T) Interactive Graphical SCADA System (IGSS) 9.0.0.11355 and earlier allow remote attackers to execute arbitrary code or cause a denial of service via a crafted packet to TCP port (1) 12397 or (2) 12399. | ||||||||
CVSS v3 Severity: | 7.3 High (CCN CVSS v3.1 Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L)
| ||||||||
CVSS v2 Severity: | 7.5 High (CVSS v2 Vector: AV:N/AC:L/Au:N/C:P/I:P/A:P) 5.5 Medium (Temporal CVSS v2 Vector: AV:N/AC:L/Au:N/C:P/I:P/A:P/E:U/RL:OF/RC:C)
5.5 Medium (CCN Temporal CVSS v2 Vector: AV:N/AC:L/Au:N/C:P/I:P/A:P/E:U/RL:OF/RC:C)
| ||||||||
Vulnerability Type: | CWE-119 | ||||||||
Vulnerability Consequences: | Gain Access | ||||||||
References: | Source: MITRE Type: CNA CVE-2011-4537 Source: CCN Type: 7-Technologies Web site Interactive Graphical SCADA System Source: OSVDB Type: UNKNOWN 77977 Source: CCN Type: OSVDB ID: 77977 7-Technologies Interactive Graphical SCADA System Unspecified Packet Parsing Remote Overflow Source: CCN Type: BID-51157 7-Technologies Interactive Graphical SCADA System Buffer Overflow Vulnerability Source: CCN Type: ICSA-11-335-01 7-TECHNOLOGIES IGSS DATA SERVER BUFFER OVERFLOW Source: MISC Type: Patch, US Government Resource http://www.us-cert.gov/control_systems/pdf/ICSA-11-355-01-7.pdf Source: XF Type: UNKNOWN igss-packets-bo(71931) Source: XF Type: UNKNOWN igss-packets-bo(71931) | ||||||||
Vulnerable Configuration: | Configuration 1: Denotes that component is vulnerable | ||||||||
BACK |