Vulnerability Name:

CVE-2013-5709 (CCN-87030)

Assigned:2013-09-11
Published:2013-09-11
Updated:2020-02-10
Summary:The authentication implementation in the web server on Siemens SCALANCE X-200 switches with firmware before 5.0.0 does not use a sufficient source of entropy for generating values of random numbers, which makes it easier for remote attackers to hijack sessions by predicting a value.
CVSS v3 Severity:8.6 High (CCN CVSS v3.1 Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H)
Exploitability Metrics:Attack Vector (AV): Network
Attack Complexity (AC): Low
Privileges Required (PR): None
User Interaction (UI): None
Scope:Scope (S): Unchanged
Impact Metrics:Confidentiality (C): Low
Integrity (I): Low
Availibility (A): High
CVSS v2 Severity:8.3 High (CVSS v2 Vector: AV:N/AC:M/Au:N/C:P/I:P/A:C)
6.1 Medium (Temporal CVSS v2 Vector: AV:N/AC:M/Au:N/C:P/I:P/A:C/E:U/RL:OF/RC:C)
Exploitability Metrics:Access Vector (AV): Network
Access Complexity (AC): Medium
Authentication (Au): None
Impact Metrics:Confidentiality (C): Partial
Integrity (I): Partial
Availibility (A): Complete
8.3 High (CCN CVSS v2 Vector: AV:N/AC:M/Au:N/C:P/I:P/A:C)
6.1 Medium (CCN Temporal CVSS v2 Vector: AV:N/AC:M/Au:N/C:P/I:P/A:C/E:U/RL:OF/RC:C)
Exploitability Metrics:Access Vector (AV): Network
Access Complexity (AC): Medium
Athentication (Au): None
Impact Metrics:Confidentiality (C): Partial
Integrity (I): Partial
Availibility (A): Complete
Vulnerability Type:CWE-189
Vulnerability Consequences:Gain Access
References:Source: MITRE
Type: CNA
CVE-2013-5709

Source: MISC
Type: US Government Resource
http://ics-cert.us-cert.gov/advisories/ICSA-13-254-01

Source: CCN
Type: SA54784
Siemens SCALANCE X-200 Series Switches Session Hijacking Weakness

Source: CCN
Type: OSVDB ID: 97207
Siemens SCALANCE X-200 PRNG Weakness Web Session Hijacking

Source: CONFIRM
Type: Vendor Advisory
http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-850708.pdf

Source: CCN
Type: SSA-850708
Authentication Bypass in SCALANCE X-200 Switch Family

Source: CONFIRM
Type: UNKNOWN
https://cert-portal.siemens.com/productcert/pdf/ssa-850708.pdf

Source: XF
Type: UNKNOWN
scalance-cve20135709-session-hijacking(87030)

Vulnerable Configuration:Configuration 1:
  • cpe:/o:siemens:scalance_x-200_series_firmware:4.3:*:*:*:*:*:*:*
  • OR cpe:/o:siemens:scalance_x-200_series_firmware:*:*:*:*:*:*:*:* (Version <= 4.4)
  • AND
  • cpe:/h:siemens:scalance_x-200:-:*:*:*:*:*:*:*
  • OR cpe:/h:siemens:scalance_x-200rna:-:*:*:*:*:*:*:*
  • OR cpe:/h:siemens:scalance_x200-4p_irt:-:*:*:*:*:*:*:*
  • OR cpe:/h:siemens:scalance_x201-3p_irt:-:*:*:*:*:*:*:*
  • OR cpe:/h:siemens:scalance_x201-3p_irt:-:-:pro:*:*:*:*:*
  • OR cpe:/h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*
  • OR cpe:/h:siemens:scalance_x202-2p_irt:-:*:*:*:*:*:*:*
  • OR cpe:/h:siemens:scalance_x202-2p_irt:-:-:pro:*:*:*:*:*
  • OR cpe:/h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*
  • OR cpe:/h:siemens:scalance_x204irt:-:-:pro:*:*:*:*:*
  • OR cpe:/h:siemens:scalance_xf-200:-:*:*:*:*:*:*:*

  • * Denotes that component is vulnerable
    BACK
    siemens scalance x-200 series firmware 4.3
    siemens scalance x-200 series firmware *
    siemens scalance x-200 -
    siemens scalance x-200rna -
    siemens scalance x200-4p irt -
    siemens scalance x201-3p irt -
    siemens scalance x201-3p irt - -
    siemens scalance x202-2irt -
    siemens scalance x202-2p irt -
    siemens scalance x202-2p irt - -
    siemens scalance x204irt -
    siemens scalance x204irt - -
    siemens scalance xf-200 -