Vulnerability Name:

CVE-2017-12723

Assigned:2017-09-07
Published:2017-09-07
Updated:2018-03-02
Summary:A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.
CVSS v3 Severity:3.7 Low (CVSS v3 Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N)
3.3 Low (Temporal CVSS v3 Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:U/RL:U/RC:R)
Exploitability Metrics:Attack Vector (AV): Network
Attack Complexity (AC): High
Privileges Required (PR): None
User Interaction (UI): None
Scope:Scope (S): Unchanged
Impact Metrics:Confidentiality (C): Low
Integrity (I): None
Availibility (A): None
3.7 Low (CCN CVSS v3 Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N)
3.3 Low (CCN Temporal CVSS v3 Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N/E:U/RL:U/RC:R)
Exploitability Metrics:Attack Vector (AV): Network
Attack Complexity (AC): High
Privileges Required (PR): None
User Interaction (UI): None
Scope:Scope (S): Unchanged
Impact Metrics:Confidentiality (C): Low
Integrity (I): None
Availibility (A): None
CVSS v2 Severity:4.3 Medium (CVSS v2 Vector: AV:N/AC:M/Au:N/C:P/I:N/A:N)
Exploitability Metrics:Access Vector (AV): Network
Access Complexity (AC): Medium
Authentication (Au): None
Impact Metrics:Confidentiality (C): Partial
Integrity (I): None
Availibility (A): None
2.6 Low (CCN CVSS v2 Vector: AV:N/AC:H/Au:N/C:P/I:N/A:N)
Exploitability Metrics:Access Vector (AV): Network
Access Complexity (AC): High
Athentication (Au): None
Impact Metrics:Confidentiality (C): Partial
Integrity (I): None
Availibility (A): None
Vulnerability Type:CWE-200
References:Source: BID
Type: VENDOR_ADVISORY
100665

Source: XF
Type: UNKNOWN
smithsmedical-cve201712723-info-disc(131645)

Source: MISC
Type: VENDOR_ADVISORY
https://ics-cert.us-cert.gov/advisories/ICSMA-17-250-02A

Vulnerable Configuration:Configuration 1:
  • cpe:/o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.1:*:*:*:*:*:*:*
  • OR cpe:/o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.5:*:*:*:*:*:*:*
  • OR cpe:/o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.6:*:*:*:*:*:*:*
  • AND
  • cpe:/h:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:-:*:*:*:*:*:*:*

  • Configuration CCN 1:
  • cpe:/o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.1:*:*:*:*:*:*:*
  • OR cpe:/o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.5:*:*:*:*:*:*:*
  • OR cpe:/o:smiths-medical:medfusion_4000_wireless_syringe_infusion_pump:1.6:*:*:*:*:*:*:*

  • * Denotes that component is vulnerable
    BACK
    smiths-medical medfusion 4000 wireless syringe infusion pump 1.1
    smiths-medical medfusion 4000 wireless syringe infusion pump 1.5
    smiths-medical medfusion 4000 wireless syringe infusion pump 1.6
    smiths-medical medfusion 4000 wireless syringe infusion pump -
    smiths-medical medfusion 4000 wireless syringe infusion pump 1.1
    smiths-medical medfusion 4000 wireless syringe infusion pump 1.5
    smiths-medical medfusion 4000 wireless syringe infusion pump 1.6