Vulnerability Name:

CVE-2019-6575 (CCN-159303)

Assigned:2019-04-09
Published:2019-04-09
Updated:2022-10-06
Summary:A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
CVSS v3 Severity:7.5 High (CVSS v3.1 Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H)
6.5 Medium (Temporal CVSS v3.1 Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C)
Exploitability Metrics:Attack Vector (AV): Network
Attack Complexity (AC): Low
Privileges Required (PR): None
User Interaction (UI): None
Scope:Scope (S): Unchanged
Impact Metrics:Confidentiality (C): None
Integrity (I): None
Availibility (A): High
7.5 High (CCN CVSS v3.1 Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H)
6.5 Medium (CCN Temporal CVSS v3.1 Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C)
Exploitability Metrics:Attack Vector (AV): Network
Attack Complexity (AC): Low
Privileges Required (PR): None
User Interaction (UI): None
Scope:Scope (S): Unchanged
Impact Metrics:Confidentiality (C): None
Integrity (I): None
Availibility (A): High
CVSS v2 Severity:7.8 High (CVSS v2 Vector: AV:N/AC:L/Au:N/C:N/I:N/A:C)
Exploitability Metrics:Access Vector (AV): Network
Access Complexity (AC): Low
Authentication (Au): None
Impact Metrics:Confidentiality (C): None
Integrity (I): None
Availibility (A): Complete
7.8 High (CCN CVSS v2 Vector: AV:N/AC:L/Au:N/C:N/I:N/A:C)
Exploitability Metrics:Access Vector (AV): Network
Access Complexity (AC): Low
Athentication (Au): None
Impact Metrics:Confidentiality (C): None
Integrity (I): None
Availibility (A): Complete
Vulnerability Type:CWE-248
Vulnerability Consequences:Denial of Service
References:Source: MITRE
Type: CNA
CVE-2019-6575

Source: CCN
Type: Siemens Web site
Siemens SIMATIC, SINEC-NMS, SINEMA, SINUMERIK, and TeleControl

Source: MISC
Type: Vendor Advisory
https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf

Source: XF
Type: UNKNOWN
siemens-cve20196575-dos(159303)

Source: CCN
Type: ICSA-19-099-03
Siemens Industrial Products with OPC UA

Vulnerable Configuration:Configuration 1:
  • cpe:/o:siemens:simatic_cp443-1_opc_ua_firmware:*:*:*:*:*:*:*:*
  • AND
  • cpe:/h:siemens:simatic_cp443-1_opc_ua:-:*:*:*:*:*:*:*

  • Configuration 2:
  • cpe:/o:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:* (Version < 2.7)
  • AND
  • cpe:/h:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*

  • Configuration 3:
  • cpe:/o:siemens:simatic_ipc_diagmonitor_firmware:*:*:*:*:*:*:*:*
  • AND
  • cpe:/h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*

  • Configuration 4:
  • cpe:/o:siemens:simatic_net_pc_software_firmware:*:*:*:*:*:*:*:*
  • AND
  • cpe:/h:siemens:simatic_net_pc_software:-:*:*:*:*:*:*:*

  • Configuration 5:
  • cpe:/o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*
  • AND
  • cpe:/h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*

  • Configuration 6:
  • cpe:/o:siemens:simatic_rf600r_firmware:*:*:*:*:*:*:*:*
  • AND
  • cpe:/h:siemens:simatic_rf600r:-:*:*:*:*:*:*:*

  • Configuration 7:
  • cpe:/o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:* (Version <= 2.5)
  • AND
  • cpe:/h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*

  • Configuration 8:
  • cpe:/a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:* (Version < 2.1)
  • OR cpe:/a:siemens:simatic_wincc_oa:*:*:*:*:*:*:*:* (Version < 3.15-p018)
  • OR cpe:/a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:simatic_wincc_runtime_comfort:*:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:simatic_wincc_runtime_hsp_comfort:*:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:simatic_wincc_runtime_mobile:*:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:sinema_server:*:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:* (Version <= 2.5)
  • OR cpe:/a:siemens:opc_unified_architecture:*:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:sinec-nms:1.0:-:*:*:*:*:*:*
  • OR cpe:/a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:* (Version < 3.1.1)
  • OR cpe:/a:siemens:sinec-nms:*:*:*:*:*:*:*:* (Version < 1.0)

  • Configuration 9:
  • cpe:/o:siemens:simatic_s7-1500f_firmware:*:*:*:*:*:*:*:* (Version <= 2.5)
  • AND
  • cpe:/h:siemens:simatic_s7-1500f:-:*:*:*:*:*:*:*

  • Configuration 10:
  • cpe:/o:siemens:simatic_s7-1500s_firmware:*:*:*:*:*:*:*:* (Version <= 2.5)
  • AND
  • cpe:/h:siemens:simatic_s7-1500s:-:*:*:*:*:*:*:*

  • Configuration 11:
  • cpe:/o:siemens:simatic_s7-1500t_firmware:*:*:*:*:*:*:*:* (Version <= 2.5)
  • AND
  • cpe:/h:siemens:simatic_s7-1500t:-:*:*:*:*:*:*:*

  • Configuration 12:
  • cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:* (Version < 15.1)
  • OR cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:-:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_1:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_2:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_3:*:*:*:*:*:*
  • AND
  • cpe:/h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*

  • Configuration 13:
  • cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:* (Version < 15.1)
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_3:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_2:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_1:*:*:*:*:*:*
  • AND
  • cpe:/h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*

  • Configuration 14:
  • cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:* (Version < 15.1)
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_1:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_2:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_3:*:*:*:*:*:*
  • AND
  • cpe:/h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*

  • Configuration 15:
  • cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:* (Version < 15.1)
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_1:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_2:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_3:*:*:*:*:*:*
  • AND
  • cpe:/h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*

  • Configuration 16:
  • cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:* (Version < 15.1)
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_1:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_2:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_3:*:*:*:*:*:*
  • AND
  • cpe:/h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*

  • Configuration 17:
  • cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:* (Version < 15.1)
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_1:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_2:*:*:*:*:*:*
  • OR cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_3:*:*:*:*:*:*
  • AND
  • cpe:/h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*

  • Configuration CCN 1:
  • cpe:/a:siemens:sinema_server:-:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:simatic_net_pc-software:-:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:simatic_wincc_oa:*:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:simatic_wincc_runtime:::advanced:*:*:*:*:*
  • OR cpe:/h:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*
  • OR cpe:/h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*
  • OR cpe:/h:siemens:simatic_rf600r:-:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:simatic_cp443-1_opc_ua:-:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:simatic_s7-1500_software_controller:2.5:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:simatic_wincc_runtime_comfort:-:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:simatic_wincc_runtime_hsp_comfort:-:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:simatic_wincc_runtime_mobile:-:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:sinec-nms:-:*:*:*:*:*:*:*
  • OR cpe:/a:siemens:sinumerik_opc_ua_server:-:*:*:*:*:*:*:*

  • * Denotes that component is vulnerable
    BACK
    siemens simatic cp443-1 opc ua firmware *
    siemens simatic cp443-1 opc ua -
    siemens simatic et 200 open controller cpu 1515sp pc2 firmware *
    siemens simatic et 200 open controller cpu 1515sp pc2 -
    siemens simatic ipc diagmonitor firmware *
    siemens simatic ipc diagmonitor -
    siemens simatic net pc software firmware *
    siemens simatic net pc software -
    siemens simatic rf188c firmware *
    siemens simatic rf188c -
    siemens simatic rf600r firmware *
    siemens simatic rf600r -
    siemens simatic s7-1500 firmware *
    siemens simatic s7-1500 -
    siemens sinumerik opc ua server *
    siemens simatic wincc oa *
    siemens simatic wincc runtime advanced *
    siemens simatic wincc runtime comfort *
    siemens simatic wincc runtime hsp comfort *
    siemens simatic wincc runtime mobile *
    siemens sinema server *
    siemens simatic s7-1500 software controller *
    siemens opc unified architecture *
    siemens sinec-nms 1.0 -
    siemens telecontrol server basic *
    siemens sinec-nms *
    siemens simatic s7-1500f firmware *
    siemens simatic s7-1500f -
    siemens simatic s7-1500s firmware *
    siemens simatic s7-1500s -
    siemens simatic s7-1500t firmware *
    siemens simatic s7-1500t -
    siemens simatic hmi comfort outdoor panels firmware *
    siemens simatic hmi comfort outdoor panels firmware 15.1 -
    siemens simatic hmi comfort outdoor panels firmware 15.1 upd_1
    siemens simatic hmi comfort outdoor panels firmware 15.1 upd_2
    siemens simatic hmi comfort outdoor panels firmware 15.1 upd_3
    siemens simatic hmi comfort outdoor panels -
    siemens simatic hmi ktp mobile panels ktp400f firmware *
    siemens simatic hmi ktp mobile panels ktp400f firmware 15.1 -
    siemens simatic hmi ktp mobile panels ktp400f firmware 15.1 upd_3
    siemens simatic hmi ktp mobile panels ktp400f firmware 15.1 upd_2
    siemens simatic hmi ktp mobile panels ktp400f firmware 15.1 upd_1
    siemens simatic hmi ktp mobile panels ktp400f -
    siemens simatic hmi ktp mobile panels ktp900 firmware *
    siemens simatic hmi ktp mobile panels ktp900 firmware 15.1 -
    siemens simatic hmi ktp mobile panels ktp900 firmware 15.1 upd_1
    siemens simatic hmi ktp mobile panels ktp900 firmware 15.1 upd_2
    siemens simatic hmi ktp mobile panels ktp900 firmware 15.1 upd_3
    siemens simatic hmi ktp mobile panels ktp900 -
    siemens simatic hmi ktp mobile panels ktp700f firmware *
    siemens simatic hmi ktp mobile panels ktp700f firmware 15.1 -
    siemens simatic hmi ktp mobile panels ktp700f firmware 15.1 upd_1
    siemens simatic hmi ktp mobile panels ktp700f firmware 15.1 upd_2
    siemens simatic hmi ktp mobile panels ktp700f firmware 15.1 upd_3
    siemens simatic hmi ktp mobile panels ktp700f -
    siemens simatic hmi ktp mobile panels ktp700 firmware *
    siemens simatic hmi ktp mobile panels ktp700 firmware 15.1 -
    siemens simatic hmi ktp mobile panels ktp700 firmware 15.1 upd_1
    siemens simatic hmi ktp mobile panels ktp700 firmware 15.1 upd_2
    siemens simatic hmi ktp mobile panels ktp700 firmware 15.1 upd_3
    siemens simatic hmi ktp mobile panels ktp700 -
    siemens simatic hmi ktp mobile panels ktp900f firmware *
    siemens simatic hmi ktp mobile panels ktp900f firmware 15.1 -
    siemens simatic hmi ktp mobile panels ktp900f firmware 15.1 upd_1
    siemens simatic hmi ktp mobile panels ktp900f firmware 15.1 upd_2
    siemens simatic hmi ktp mobile panels ktp900f firmware 15.1 upd_3
    siemens simatic hmi ktp mobile panels ktp900f -
    siemens sinema server -
    siemens telecontrol server basic *
    siemens simatic net pc-software -
    siemens simatic wincc oa *
    siemens simatic wincc runtime
    siemens simatic et 200 sp open controller cpu 1515sp pc2 -
    siemens simatic ipc diagmonitor -
    siemens simatic rf188c -
    siemens simatic rf600r -
    siemens simatic cp443-1 opc ua -
    siemens simatic s7-1500 software controller 2.5
    siemens simatic wincc runtime comfort -
    siemens simatic wincc runtime hsp comfort -
    siemens simatic wincc runtime mobile -
    siemens sinec-nms -
    siemens sinumerik opc ua server -