Vulnerability Name: | CVE-2020-25239 (CCN-197942) | ||||||||||||
Assigned: | 2020-09-10 | ||||||||||||
Published: | 2021-03-09 | ||||||||||||
Updated: | 2021-03-18 | ||||||||||||
Summary: | A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). The webserver could allow unauthorized actions via special urls for unpriviledged users. The settings of the UMC authorization server could be changed to add a rogue server by an attacker authenticating with unprivilege user rights. | ||||||||||||
CVSS v3 Severity: | 8.8 High (CVSS v3.1 Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) 7.7 High (Temporal CVSS v3.1 Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C)
7.7 High (CCN Temporal CVSS v3.1 Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C)
| ||||||||||||
CVSS v2 Severity: | 6.5 Medium (CVSS v2 Vector: AV:N/AC:L/Au:S/C:P/I:P/A:P)
| ||||||||||||
Vulnerability Type: | CWE-863 | ||||||||||||
Vulnerability Consequences: | Bypass Security | ||||||||||||
References: | Source: MITRE Type: CNA CVE-2020-25239 Source: CONFIRM Type: Vendor Advisory N/A Source: CCN Type: Siemens Security Advisory SSA-731317 Multiple vulnerabilities in SINEMA Remote Connect Web Based Management Source: XF Type: UNKNOWN siemens-cve202025239-sec-bypass(197942) Source: CCN Type: ICSA-21-068-04 Siemens SINEMA Remote Connect Server | ||||||||||||
Vulnerable Configuration: | Configuration 1: Configuration CCN 1: ![]() | ||||||||||||
BACK |