Vulnerability Name:

CVE-2023-38097 (CCN-260596)

Assigned:2023-07-13
Published:2023-07-13
Updated:2023-07-13
Summary:Netgear ProSAFE Network Management System could allow a remote authenticated attacker to execute arbitrary code on the system, caused by exposing dangerous functions in BkreProcessThread. By sending a specially crafted request, an attacker could exploit this vulnerability to execute arbitrary commands on the system.
CVSS v3 Severity:7.2 High (CCN CVSS v3.1 Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H)
6.3 Medium (CCN Temporal CVSS v3.1 Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C)
Exploitability Metrics:Attack Vector (AV): Network
Attack Complexity (AC): Low
Privileges Required (PR): High
User Interaction (UI): None
Scope:Scope (S): Unchanged
Impact Metrics:Confidentiality (C): High
Integrity (I): High
Availibility (A): High
CVSS v2 Severity:9.0 High (CCN CVSS v2 Vector: AV:N/AC:L/Au:S/C:C/I:C/A:C)
Exploitability Metrics:Access Vector (AV): Network
Access Complexity (AC): Low
Athentication (Au): Single_Instance
Impact Metrics:Confidentiality (C): Complete
Integrity (I): Complete
Availibility (A): Complete
Vulnerability Consequences:Gain Access
References:Source: MITRE
Type: CNA
CVE-2023-38097

Source: XF
Type: UNKNOWN
netgear-cve202338097-code-exec(260596)

Source: CCN
Type: NETGEAR Security Advisory PSV-2023-0024 & PSV-2023-0025
Security Advisory for Multiple Vulnerabilities on the ProSAFE Network Management System, PSV-2023-0024 & PSV-2023-0025

Source: CCN
Type: ZDI-23-919
NETGEAR ProSAFE Network Management System BkreProcessThread Exposed Dangerous Function Remote Code Execution Vulnerability

Vulnerable Configuration:Configuration CCN 1:
  • cpe:/h:netgear:prosafe:*:*:*:*:*:*:*:*

  • * Denotes that component is vulnerable
    BACK